Letters and short codes on a height display: rES, E-1 … E-4, ovr, dut. The instruction is published by DewertOkin as its AB02 handset file and describes a 29 V DC two-column desk with memory keys 1–3 and an S key.
Error codes
| Display | Meaning | What to do |
|---|---|---|
rES / E-1Reset needed | Manual reset required or in progress. | Run the manual reset: hold DOWN until the desk lowers, rises slightly and shows the lowest height. It is needed after installation and after a power loss. |
E-2Fix yourself | Anti-collision triggered by an obstacle. | The desk reverses a short distance by itself. Remove the obstacle; normal use is then possible. |
E-3Reset needed | Motor or plug detection fault. | Check that every cable is firmly connected. Unplug the main cable, wait at least 5 seconds, plug it back in and then perform the manual reset. |
E-4Reset needed | The two legs differ in height by more than 1 inch (about 2.5 cm). | Stop using the desk and perform the manual reset so both columns re-synchronise. |
ovrFix yourself | Overload. | Remove load from the desktop. The instruction states the overload threshold as 1000 N (102 kg / 225 lb), while its technical data list 800 N maximum load — stay within the lower figure. |
dutFix yourself | Duty-cycle protection: operated too long without a rest. | Let the desk rest for about 18 minutes (duty cycle 2 min on / 18 min off). |
Reset step by step
- Keep the travel path clear: anti-collision is not active during every reset.
- Press and hold DOWN until the display alternates between “E-1” and “rES”, then release.
- Press and hold DOWN again. The desk lowers slowly, then rises slightly until the display shows “27.6”.
- Release the key. The desk is ready for normal use.
Save a memory position
- Move to the desired height.
- Hold S until the display shows “S - -”.
- Press 1 (the display alternates “S-1” and the height), then press S to store. Repeat with 2 or 3.
Switch cm / inch
- Hold S until “S - -” appears.
- Press UP until “Unt” is shown.
- Press 1 for centimetres or 2 for inches, then S to save.
Set or clear height limits
- Hold S until “S - -” appears, then press UP until “HLP” flashes.
- Press 1 (“H-P”), move to the upper limit and press S; press 2 (“L-P”), move to the lower limit and press S.
- The instruction advises using limits only when needed. A factory reset (“FAC”) clears them.
Factory reset
- Hold S until the display shows “FAC”, then press S again.
- This clears memory positions and height limits. Run the normal reset afterwards if “rES” appears.
Technical data in the document
| Input | 100–240 V AC |
|---|---|
| Output | 29 V DC |
| Max. load (technical data) | 800 N / 82 kg / 180 lb |
| Height range (without top) | 70–120 cm (27.6–47.3 in) |
| Duty cycle | 2 min on / 18 min off |
Common questions
Why does my desk show E-1 after a power cut?
On this system E-1/rES means the controller has lost its position reference. Hold DOWN through the reset sequence until the display shows the lowest height (27.6 in).
Is E-3 a broken motor?
Not necessarily. The documented first step is a cable check and a 5-second power disconnect, followed by a reset. If it returns, contact the desk supplier.
Source
Summarised by KUVEV. The manual supplied with your furniture takes precedence if it differs.